Oem Fire Rated Insulated Metal Wall Panels China Factory

Core decision: mineral wool vs. PIR vs. phenolic. Mineral wool handles 1000°C+ without melting but adds 3-5 kg/m² over PIR at the same fire rating. PIR gives the thinnest profile for a given R-value

oem fire rated insulated metal wall panels china factory - Bulk Supply and Specification Guide

Material Options and Their Trade-offs

Core decision: mineral wool vs. PIR vs. phenolic. Mineral wool handles 1000°C+ without melting but adds 3-5 kg/m² over PIR at the same fire rating. PIR gives the thinnest profile for a given R-value yet chars above 300°C, so the facer and joint detail carry the rating. Phenolic sits between them on both weight and temperature resistance but costs 15-25% more per square metre.

Facer alloy matters as much as the core. 0.5-0.7 mm G300-Z275 galvanised steel is standard for internal partitions; 0.6-0.8 mm AZ150 aluminium-zinc or 0.7 mm PVDF-coated steel becomes the default once the panel sees exterior cycles, coastal salt, or industrial fallout. The 25 µm PVDF topcoat keeps ΔE < 3 after 2000 h QUV-A, whereas standard polyester hits ΔE 6-8 in the same test.

Adhesive line survival is the quiet failure mode. Two-component polyurethane with 1.2-1.5 N/mm² shear at 23°C drops to 0.4 N/mm² at 80°C unless a high-temperature formulation is specified. We qualify each batch on a 90°C/90% RH soak for 168 h followed by a 4-point bend at 5 mm/min — panels that delaminate before 1.0 kN/m are rejected.

Size, Weight and Specification Range

Parameter Standard Range Custom Window Tolerance
Effective width 1000 / 1150 / 1200 mm 900-1250 mm in 50 mm steps ±2 mm
Length 2000-13500 mm Up to 16000 mm with splice joint ±3 mm
Core thickness 50 / 75 / 100 / 150 / 200 mm 40-250 mm ±2 mm
Weight (mineral wool 100 mm) 14.5-16.8 kg/m² 12-22 kg/m² depending on facer ±5%
Fire rating (EN 13501-1) A2-s1,d0 / B-s1,d0 A1 achievable with ceramic fibre core Class only
Thermal conductivity λ 0.038-0.042 W/m·K (MW) 0.021-0.024 W/m·K (PIR) ±0.002 W/m·K

Lengths above 12 m ship on extendable trailers; the 16 m option requires a factory splice with a 300 mm internal steel spline and intumescent sealant — adds 1.2 kg/m but keeps the fire line continuous. Panel squareness is held to 1 mm/m diagonal difference; anything wider binds in the clip system and leaks air at 50 Pa.

Segment-Specific Requirements

Healthcare & Pharma Cleanrooms

ISO 5-7 zones demand zero particle shed. We supply panels with 0.6 mm stainless steel 316L facers, electropolished to Ra ≤ 0.4 µm, and silicone-sealed joints that survive 200 vaporised hydrogen peroxide cycles without discoloration. Core is phenolic — no fibre migration.

Weight penalty: +2.5 kg/m² over standard galvanised. Lead time stretches to 45 days for the stainless coil allocation.

Cold-Store & Food Processing

-30°C to +10°C daily swing. PIR core with 0.7 mm PVC plastisol (150 µm) facer resists impact from forklift forks and holds λ ≤ 0.022 W/m·K after 10 years. Joint detail uses a double-lip EPDM gasket compressed to 30% — maintains 0.15 m³/h·m² air leakage at 50 Pa.

Condensation risk at the floor track is the spec killer. We supply a thermal-break base channel with 5 mm polyamide strip as standard on cold-store orders.

oem fire rated insulated metal wall panels china factory

Data centres specify A2-s1,d0 mineral wool at 150 mm minimum for 120-minute compartmentation. The trade-off: 18.5 kg/m² loads the slab and requires M12 through-bolts at 600 mm centres instead of the usual M10 clips. We provide the structural calc pack with every quote so the consultant can sign off without a separate engineer review.

Working as a Production Partner, Not a Catalogue Supplier

Every project starts with a marked-up GA drawing and a fire strategy report. We return a fabrication model in IFC or STEP within 5 working days showing panel layout, joint sequencing, penetration sleeves, and the exact clip pattern for the declared wind load. No production order is cut until the client signs the model and the first-article inspection report (FAIR) on the pilot run — typically 3 panels from the actual coil batch.

Colour matching follows a ΔE ≤ 1.5 protocol against the client's RAL or custom spectrophotometer target. We keep a 50 m master coil for each project so repeat orders 18 months later still match the original elevation. Touch-up paint pens are mixed from the same batch and shipped in the spare-parts crate.

Artwork & branding: Laser-etching the facade panel rear face with project code, panel ID, and production date is included at no extra cost. Front-face silk-screen logos require a 30-day lead for screen making and a minimum 500 m² run — below that, we supply adhesive-backed aluminium tags rated for 15 years UV.

Serviceability is designed in. All external panels use a revealed-fixing clip that allows single-panel removal without disturbing neighbours — critical for facade access in high-rise. The clip cavity is 22 mm deep to accept a 19 mm socket; we supply two installation keys per 100 m² order.

Quality Control and Batch Consistency

Check Point Method Frequency Acceptance
Incoming coil thickness & zinc weight Eddy current + gravimetric Every coil EN 10346 ±0.02 mm / ±15 g/m²
Core density & fibre shot content Core sample / sieve analysis Every 500 m² ±5% nominal density, shot < 15%
Adhesive coat weight Gravimetric on test strip Every shift start 180-220 g/m² ±10%
Dimensional check (L/W/T/Squareness) CMM or laser tracker First 3 panels + 1/500 thereafter Per table tolerances above
Peel adhesion (90°) ASTM D1781 @ 50 mm/min Every 1000 m² ≥ 1.2 N/mm² (23°C), ≥ 0.7 N/mm² (80°C)
Fire performance witness test EN 13823 (SBI) on production sample Every new core batch + annually FIGRA ≤ 120 W/s (A2), ≤ 250 W/s (B)

Traceability: each panel carries a QR-coded label on the male joint linking to the coil certificates, adhesive lot, press cycle parameters, and the FAIR PDF. The database is retained for 10 years — useful when a specifier asks for proof on year 7.

Packaging is engineered for site logistics, not just container fill. Standard export pack: panels stacked face-to-face on treated timber bearers at 1200 mm centres, interleaved with 200 µm PE foam, edge-protected with 3 mm corrugated cardboard, strapped with 19 mm PET banding at 600 N tension. A 40'HQ takes 1100 m² of 100 mm mineral wool panels at 24 t gross — legal for most Asian ports without special permit.

Request a Project Sample Pack

Send us the GA drawing, fire strategy, and target U-value. We return a 300 × 300 mm corner sample with the exact facer, core, and joint profile — plus the FAIR template your consultant expects — within 10 working days.

Start the sample request →